Front Loader, Double Column & Master Door (No Parcel Compartment):

Type V111-3:
(3 unit minimum:)
28 inches minimum to 32 inches maximum customer compartment (interior bottom shelf) from the finished floor.
36 inches minimum to 48 inches maximum customer compartment above the finished floor.
48 inches minimum to 67 inches maximum USPS Arrow lock above the finished floor.

Type V111-19:
(19 unit:)
28 inches minimum customer compartment (interior bottom shelf) from the finished floor.
36 inches minimum to 48 inches maximum customer compartment above the finished floor.
48 inches minimum to 67 inches maximum USPS Arrow lock above the finished floor.

67 inches Max to Patron Lock.

Notes - All units shall be designed such that they are in compliance with the following installation requirements:

  1. At least one customer compartment shall be positioned less than 48 inches from the finished floor.
  2. No parcel locker compartment (interior bottom shelf) shall be positioned less than 15 inches from the finished floor.
  3. No patron lock shall be located more than 67 inches above the finished floor.
  4. No customer compartment (interior bottom shelf) shall be positioned less than 28 inches from the finished floor.
  5. The USPS Arrow lock shall be located between 36 and 48 inches above the finished floor.