Rear Loader, Double Column:
Type V-3:
(3 unit minimum:)
15 inches minimum to parcel locker compartment (interior bottom shelf) from the finished floor.
28 inches minimum to 32 inches maximum customer compartment (interior bottom shelf) from the finished floor.
36 inches minimum to 48 inches maximum USPS Arrow lock above the finished floor.
Type V-8:
(8 unit:)
15 inches minimum parcel locker compartment (interior bottom shelf) from the finished floor.
28 inches minimum customer compartment (interior bottom shelf) from the finished floor.
36 inches minimum to 48 inches maximum USPS Arrow lock above the finished floor.
Type V-16:
(16 unit Max:)
15 inches minimum parcel locker compartment (interior bottom shelf) from the finished floor.
28 inches minimum to 32 inches maximum customer compartment (interior bottom shelf) from the finished floor.
48 inches minimum to 67 inches maximum USPS Arrow lock above the finished floor.
67 inches Max to Patron Lock.
Notes - All units shall be designed such that they are in compliance with the following installation requirements:
Back to the U.S. POSTAL SERVICE STANDARD WALL-MOUNTED CENTRALIZED MAIL RECEPTACLES page.